Our Water Recycling & Reuse Feasibility Services
Wudbox evaluates water recovery opportunities across industrial processes, utilities and wastewater treatment systems. The assessment considers the characteristics of individual water streams and their suitability for different reuse applications.
1. Water Stream Identification & Recovery Assessment
The first step is to identify water streams generated across the facility that may be suitable for recycling or reuse.
This includes reviewing wastewater sources, existing treatment systems, water consumption patterns and current discharge practices.
Our assessment covers:
- Identification of process wastewater streams.
- Assessment of cooling tower blowdown and utility wastewater.
- Review of equipment washing and cleaning water.
- Evaluation of rinsing and washing operations.
- Assessment of relatively low-contamination water streams.
- Review of treated effluent currently discharged.
- Identification of opportunities for segregation and recovery.
The objective is to identify recoverable water streams and understand their potential contribution to the facility’s overall water requirements.
2. Wastewater Quality & Treatment Requirement Assessment
Water quality determines whether a particular stream can be reused directly or requires additional treatment.
We evaluate available wastewater quality information, including laboratory reports, process records and existing treatment performance data, to understand the characteristics of each stream.
Parameters may include:
- pH and temperature.
- Biochemical Oxygen Demand (BOD).
- Chemical Oxygen Demand (COD).
- Total Suspended Solids (TSS).
- Total Dissolved Solids (TDS).
- Oil and grease.
- Chlorides and sulphates.
- Hardness and alkalinity.
- Nutrients and relevant heavy metals.
- Industry-specific contaminants, where applicable.
Based on the intended reuse application, the assessment identifies the water quality requirements and the treatment processes that may be necessary.
Where additional testing is required, representative sampling and laboratory analysis can be coordinated with suitable testing facilities.
3. Reuse Application Identification
Recycled water must meet the quality requirements of its intended application. Water suitable for one process may not be appropriate for another.
Wudbox evaluates potential reuse applications by examining process requirements, water quality specifications, operational constraints and existing infrastructure.
Potential applications include:
a. Cooling Tower Makeup
Treated wastewater may be considered for cooling tower makeup, subject to requirements relating to dissolved solids, hardness, scaling, corrosion, microbiological growth and other operating conditions.
b. Boiler Feedwater
Reuse in boiler systems generally requires stringent water quality controls. Additional treatment such as softening, reverse osmosis or demineralisation may be necessary, depending on boiler pressure and feedwater specifications.
c. Process Water
Treated water may be suitable for selected manufacturing processes where its quality meets product, process and equipment requirements.
d. Equipment Washing & Floor Cleaning
Appropriately treated water may be reused for equipment cleaning, floor washing and other non-product-contact applications.
e. Gardening & Landscaping
Treated wastewater may be considered for landscaping and irrigation, subject to applicable reuse standards, salinity, microbiological quality and site-specific conditions.
f. Dust Suppression & Utility Applications
Selected treated water streams may be reused for dust suppression and other utility applications where water quality and operational requirements permit.
Each application is evaluated independently rather than assuming that treated effluent can be reused across all facility operations.
4. Treatment Technology & System Feasibility
Once potential reuse applications have been identified, the next step is to evaluate the treatment technologies required to achieve the desired water quality.
The assessment considers existing treatment infrastructure, wastewater characteristics, treatment objectives, recovery requirements and operational conditions.
Potential treatment technologies include:
a. Filtration Systems
Used to remove suspended solids and particulate matter. Depending on water quality, options may include pressure sand filters, multimedia filters and other filtration arrangements.
b. Activated Carbon Filtration
May be considered for reducing certain dissolved organic compounds, colour, odour and residual contaminants, depending on the wastewater characteristics.
c. Membrane Filtration
Technologies such as ultrafiltration (UF) and microfiltration (MF) can help remove suspended solids, colloidal particles and microorganisms, depending on membrane characteristics and system configuration.
d. Reverse Osmosis (RO)
RO may be considered where dissolved salts and other dissolved constituents need to be reduced to meet reuse water quality requirements.
e. Softening & Demineralisation
These processes may be required for applications sensitive to hardness, dissolved minerals and conductivity, including certain utility and process requirements.
f. Biological Treatment
Biological processes may be relevant where biodegradable organic pollutants need to be reduced before further treatment or reuse.
g. Advanced Oxidation & Disinfection
Depending on the contaminants and intended reuse, additional treatment may be required to address specific organic compounds or microbiological risks.
The feasibility assessment identifies potentially suitable treatment combinations and their technical considerations. Final technology selection requires detailed engineering, design parameters and, where appropriate, pilot testing.
5. Water Recovery & Reuse System Assessment
A recycling system must integrate with the facility’s existing water distribution, treatment and operational infrastructure.
We evaluate how recovered water can be collected, treated, stored and supplied to suitable reuse points.
The assessment considers:
- Existing wastewater collection and treatment infrastructure.
- Availability and capacity of existing ETP/STP systems.
- Potential modifications to existing treatment processes.
- Additional treatment and polishing requirements.
- Treated water storage requirements.
- Reuse distribution networks and pumping arrangements.
- Segregation of incompatible water streams.
- Operational reliability and maintenance requirements.
- Monitoring and water quality control requirements.
This helps determine whether existing infrastructure can be adapted or whether additional treatment and distribution systems may be required.
6. Zero Liquid Discharge (ZLD) & High-Recovery Options
For facilities with high wastewater generation, limited discharge options or specific regulatory requirements, advanced water recovery and Zero Liquid Discharge (ZLD) systems may also be evaluated.
ZLD feasibility requires a detailed understanding of wastewater composition, dissolved solids, recovery potential, concentrate management, energy consumption and residual waste handling.
Potential treatment stages may include:
- Wastewater segregation and pretreatment.
- Biological or physicochemical treatment.
- Ultrafiltration and reverse osmosis.
- Multiple-effect evaporation (MEE).
- Mechanical Vapour Recompression (MVR).
- Evaporation and crystallisation.
- Concentrate and salt management.
The assessment considers the technical and economic implications of these options, including energy demand, chemical consumption, maintenance requirements and disposal or recovery of residual solids.
ZLD is not automatically the most suitable solution for every facility. Its feasibility must be assessed against the site’s water balance, wastewater characteristics, regulatory requirements and cost considerations.
Assessing the Technical & Economic Feasibility of Water Reuse
A technically possible recycling system may not necessarily be commercially viable. Treatment requirements, energy consumption, chemical usage, maintenance and infrastructure costs can significantly influence the overall economics of a project.
Wudbox evaluates potential water reuse opportunities across key feasibility parameters.
A. Technical Feasibility
- Availability and consistency of wastewater streams.
- Existing wastewater quality and treatment performance.
- Required treated water quality for the intended application.
- Compatibility with existing processes and utilities.
- Treatment technology suitability.
- Expected recovery and reject streams.
- Infrastructure and operational requirements.
B. Economic Feasibility
- Estimated capital expenditure (CAPEX).
- Operating expenditure (OPEX).
- Energy and chemical consumption.
- Membrane replacement and maintenance requirements.
- Sludge, concentrate and residual waste management costs.
- Potential reduction in freshwater procurement.
- Potential reduction in wastewater discharge and disposal costs, where applicable.
- Indicative payback and financial viability.
The economic assessment uses available facility data and clearly stated assumptions. Actual savings and project returns will depend on final system design, operating conditions, water tariffs and implementation costs.